A pulse bag filter is a continuous-duty dust collection device that cleans its fabric tubes inline with a short, high-pressure burst of compressed air, so the unit never stops for manual bag shaking. This reference is built around the numbers engineers need: housing dimensions, filter areas, air-to-cloth ratios, model capacities, media ratings and the operating limits that decide whether a unit meets emission targets and keeps meeting them for years. Treat the tables below as a specification worksheet for a real process.
The table lists the typical value envelope for a mid-size pulse-jet baghouse before add-on options. Values are ranges because one family spans several chamber counts and bag lengths.
| Parameter | Symbol | Typical range | Unit / note |
|---|---|---|---|
| Air volume handled | Q | 3,000 to 120,000 | m3/h, per unit |
| Total filter area | A | 30 to 2,400 | m2, by bag count |
| Air-to-cloth ratio | AV | 0.8 to 3.5 | m/min, pulse-jet |
| Operating pressure drop | DP | 1.0 to 2.0 | kPa, normal cake |
| Cleaning air pressure | Pc | 0.4 to 0.7 | MPa, at valve |
| Pulse duration | Tp | 0.08 to 0.15 | s, per blast |
| Inlet temperature | Ti | ambient to 260 | deg C, media based |
| Filtration efficiency | E | 99.5 to 99.99 | % by weight |
| Bag diameter | Db | 120 to 160 | mm, standard |
| Bag length | Lb | 2.0 to 6.0 | m, single tube |
These figures are the starting point for sizing. The air-to-cloth ratio is the most influential number because it sets pressure drop, bag life and housing size together.
Manufacturers group pulse bag filters into series by chamber layout and bag arrangement. The comparison below maps common series classes to the duty they fit, so a specifier can shortlist a few families.
| Series class | Filter area (m2) | Airflow (m3/h) | Typical duty | Footprint |
|---|---|---|---|---|
| Single-chamber, 2 m bag | 30 to 180 | 3,000 to 20,000 | Workshop welding, bins | Compact, skid |
| Single-chamber, 3 m bag | 60 to 360 | 6,000 to 40,000 | Woodworking, packaging | Medium, indoor |
| Multi-chamber, 4 m bag | 200 to 1,200 | 20,000 to 80,000 | Cement, grain | Large, outdoor |
| Multi-chamber, 6 m bag | 400 to 2,400 | 40,000 to 120,000 | Mineral, chemical | Very large, modular |
The following table converts a process brief into the parameters a supplier quote should reference. Fill each row from measured plant data, because an understated airflow is the most common cause of a unit that never reaches spec.
| Selection input | How to determine | Design rule |
|---|---|---|
| Total gas flow | Sum all hoods, ducts and vents | Add ten to fifteen percent spare |
| Dust load inlet | Gravimetric sample at worst | Size hopper for peak |
| Particle size spread | Diffraction or sieve test | Finer median lowers safe AV |
| Peak temperature | Logger over full cycle | Match media to peak |
| Moisture and dew point | Gas analysis at inlet | Keep metal above dew point |
| Abrasion / stickiness | Dust trait review | Choose finish and inlet defence |
| Explosion class | Dust screening test | Add venting and isolation if needed |
| Target emission | Permit or internal limit | Size AV and media for limit |
Media sets the temperature ceiling, chemical resistance and release. The table collects the reference envelope for common felts used in pulse bag filters.
| Media | Temp ceiling (deg C) | Release | Chemical | Typical use |
|---|---|---|---|---|
| Polyester, scrim | 130 | Good | Fair | Wood, grain, dry |
| Polyester, oil-water finish | 130 | Very good | Improved | Moist or oily dust |
| Polypropylene | 90 | Good | Excellent | Acid, wet, chemical |
| Aramid | 200 | Good | Good | Asphalt, metal, hot |
| P84 / polyimide | 240 | Very good | Good | High-temp mineral |
| PTFE membrane | 260 | Excellent | Excellent | Fine, sticky, corrosive |
| Fiberglass with finish | 260 | Fair | Good | High temp flue gas |
| Antistatic blend | media dependent | Good | Per base fibre | Combustible dust |
Cleaning energy is a short blast through a venturi at the bag mouth. The balance of supply pressure, pulse width, nozzle size and tube length decides whether the cake releases fully or merely compacts lower down the bag.
| Cleaning variable | Setting range | Effect when raised |
|---|---|---|
| Supply pressure | 0.4 to 0.7 MPa | Stronger release, more air used |
| Pulse width | 0.08 to 0.15 s | More energy, over-clean risk |
| Pulse interval | 10 to 120 s | Longer cake, higher DP |
| Nozzle diameter | 10 to 30 mm | Wider spread, better clean |
| Tank volume | matched to blasts | Steadier pressure |
| Sequencing | row by row | Neighbours keep filtering |
A well-tuned sequence cleans one row at a time while the rest of the chamber keeps filtering, so total flow is hardly affected. Cleaning too often strips the protective cake and shortens bag life; cleaning too rarely lets pressure drop drift upward and can starve the fan.
Housing geometry affects both performance and installation cost. The layout table gives the proportional rules used when arranging tubes on the tube sheet and sizing the hopper beneath them.
| Dimension | Rule of thumb | Reason |
|---|---|---|
| Tube spacing | 1.5 to 2.0 x diameter | Avoid bag re-entrainment |
| Tube sheet thickness | matched to flange load | Stays flat, no leak |
| Hopper angle | 60 deg or steeper | Free flow, no bridge |
| Inlet velocity | below 18 m/s | Pre-settle coarse |
| Clean plenum height | 0.8 to 1.2 m | Even flow to fan |
| Access walkway | minimum 0.8 m | Safe access |
The same hardware behaves differently across dusts. The table lists a recommended air-to-cloth starting point for several common materials.
| Dust type | Suggested AV (m/min) | Media note | Watch item |
|---|---|---|---|
| Wood sanding | 2.5 to 3.5 | Polyester, anti-static | Fire, spark defence |
| Grain / flour | 2.0 to 3.0 | Polyester, food grade | Explosion venting |
| Cement / lime | 1.0 to 1.8 | Polyester or aramid | Abrasion at inlet |
| Metal fume | 1.2 to 2.0 | PTFE or fine felt | Very fine, sticky |
| Welding smoke | 1.5 to 2.5 | Polyester with finish | Oil and moisture |
| Chemical powder | 0.8 to 1.5 | PP or PTFE | Corrosion, reactivity |
Pulse cleaning needs dry, oil-free air, or the media wets out and the cake packs. The utility table estimates air demand for the plant system.
| Utility item | Indicative value | Comment |
|---|---|---|
| Air per pulse | 0.02 to 0.08 | m3 per blast |
| Pulses per minute | 2 to 20 | By chamber size and load |
| Pressure dew point | at least 10 below min | Prevents condensation |
| Oil content | below 1 mg/m3 | Protects media |
| Electric load | fan plus controls | Fan dominates cost |
| Noise at valve | typically 85 to 100 | dB(A), silencer if near staff |
Undersized or wet plant air is the hidden cause of many complaints. When valve pressure sags during a sequence, the last rows never get a full blast and pressure drop climbs until someone blames the bags.
Running cost is dominated by fan power, which scales with airflow and pressure drop. The figures show why holding pressure drop in range matters more than shaving the bag price.
| Cost driver | Lever | Effect |
|---|---|---|
| Fan power | Lower stable DP | Cuts electricity every running hour |
| Bag change | Right media and AV | Extends interval, fewer stops |
| Compressed air | Tuned pulse | Less wasted blast volume |
| Downtime | Trend monitoring | Fewer surprise outages |
| Disposal | Controlled capture | Cleaner, cheaper handling |
Outlet concentration is what permits and neighbours care about. The table links the controllable inputs to the stack result so the design team can defend the number.
| Controllable input | Target | Result if neglected |
|---|---|---|
| Air-to-cloth ratio | within media limit | Rising outlet at peak |
| Tube sheet seal | zero bypass | Direct emission leak |
| Cake stability | avoid over-clean | Loss of fine capture |
| Bag inspection | regular trend | Late failure discovery |
| Inlet distribution | even across rows | Local overload |
Before sending a specification, confirm each line is filled with measured data. A complete sheet returns a comparable quote and avoids silent upgrades that appear later as change orders.
The tables are linked. Start from airflow and dust type to pick an air-to-cloth ratio, use it with the model series table to size filter area, then confirm the media table supports the temperature and chemistry, and tune the cleaning and utility tables to the plant systems. Reading them in isolation is how mismatches slip through.
Copyright © 2025-2026 Botou Yilida Environmental Protection Machinery and Equipment Co., Ltd All Rights Reserved